Innisfail · Case study
Innisfail gym: old unit out, 12.5kW Mitsubishi in.
Stop by stop
5 stops on the job
-
Gym floorGym floor
The old under-ceiling head sat high on the wall above the gym windows.
-
Old condenserOld condenser
The outdoor unit was heavily soiled with mould and moss.
-
Panels offPanels off
Cover off, the compressor showed the state of the internals. It had done its time.
-
New arrivalNew arrival
The new Hyper Inverter condenser turned up on a timber pallet.
-
Up the wallUp the wall
Refrigeration pipework and cabling run up the corrugated wall.
Drag to compare
Same corner, new unit

The tricky bit
Working off the ladder
We ran the refrigeration pipework and cabling up the corrugated wall, working off a ladder to reach the internal head.
The result
New system, same corner
The old under-ceiling unit and its weathered condenser are gone, and Pappy's Gym now runs on a new Mitsubishi Heavy Industries 12.5kW system. The outdoor unit sits in the same corner with the pipework run up the wall, ready for the Innisfail heat.
Running 6 Aug 2026
- Brand
- Mitsubishi Heavy Industries
- System
- 12.5kW Hyper Inverter
- Removed
- Old under-ceiling system
- Where
- Innisfail
Full job notes
From an aged, mould-covered outdoor unit to a new Mitsubishi Heavy Industries 12.5kW install.
Pappy's Gym in Innisfail had an old under-ceiling air conditioner that had reached the end of its run. The outdoor condenser was heavily soiled with mould and moss, and the internal head unit sat high on the wall above the gym windows. We were called in to remove the old system and install a new Mitsubishi Heavy Industries 12.5kW unit.
We started at the outdoor unit. The old twin-fan condenser came apart panel by panel. Once the cover was off you could see the compressor and the state of the internals. It had done its time. We dismantled it and got it off the wall.
Inside, the old under-ceiling head unit was pulled down from above the windows. That side of the gym looks out over town, so we kept the run tidy against the corrugated wall.
The new Mitsubishi Heavy Industries Hyper Inverter condenser turned up on a timber pallet and we positioned it against the exterior wall in the same corner. From there we ran the refrigeration pipework and cabling up the wall, working off a ladder to reach the internal head. Drainage went in beside the pipe run.
With the new outdoor unit set in place, we finished off the connections up top. This was a like-for-like replacement done in two visits, with the removal on the first and the new unit going in on the second.
Commercial spaces like a gym cop a fair bit of heat from bodies and equipment, so a unit sized right for the room matters. The 12.5kW suits the space above the windows where the old head used to hang.
We do this sort of work across the region. If you want to see more, have a look at our other jobs around Innisfail. It's straightforward work, but a fresh unit makes a difference for a room full of people.
Mitsubishi Heavy Industries 12.5kW
A new Hyper Inverter unit sized for the gym floor, replacing the old under-ceiling system above the windows.
Full removal and replacement
The aged outdoor condenser and internal head unit were both taken out before the new gear went in.
Tidy pipe run
Refrigeration pipework, cabling and drainage were run up the corrugated exterior wall and kept neat.
What we did
- Removed the old twin-fan outdoor condenser, heavily soiled with mould and moss
- Pulled down the old under-ceiling head unit mounted above the gym windows
- Positioned the new Mitsubishi Heavy Industries 12.5kW Hyper Inverter outdoor unit against the exterior wall
- Ran refrigeration pipework and cabling up the corrugated wall
- Installed drainage alongside the pipe run
- Completed the connections and set the new system running